A leading brand in clean air systems for healthcare industry.
MATERIAL
1.2mm thickness S.S. 304 sheets. S.S. Grill having holes with max. opening with Peripheral Lighting.
FILTER DESIGN
Complete HEPA Filter full size Grid with Mini Pleat HEPA Filters. Each HEPA of 1000CFM. Mini Pleat HEPA filters are compact & separator less. Mini Pleat made from Borosilicate Glass Fibre Media (Imported from Europe/US) with 99.995% efficiency down to 0.3μ Grade H14 (EN 1822).
CLEANINESS
Class 100 / ISO Class 5 Cleanliness near grill.
AIR VELOCITY
90 - 125 FPM near grill.
Ceiling Laminar Flow with HEPA filter and Grill
The system gives Class 100 / ISO Class 5 Cleanliness near Grill.
Mini Pleat Media is Anti-Microbial treated thereby killing bacteria when it comes in contact, thereby no growth of any fungi behind media. It is cladded with thermo break insulation system. Ceiling Suspended Plenum is Compact and Sleek Designed.
Air Conditioning
Incorporates imported scroll compressor Copland/Manurop/ equivalent.
Consumes 20% less power. It comes with Condenser Coil, Condenser Fan, proper Copper Piping, Expansion Valve, Dryer, Thermostat and powder coated bracket.
4 Tr ( 2 + 2 Ton - 2 units )
6 Tr ( 3 + 3 Ton - 2 units )
8 Tr ( 4 + 4 Ton - 2 units )
Ducting
Proper curves & bends for smooth airflow. It will be tailor-made to match your OT’s construction & ceiling suspended with hangers. It will be made leak proof by sealing with silicon sealant.
Made GI/Aluminium sheet 22/24g. It has 13mm thick insulation laminated with 30μ thick aluminium foil. The supply ducting is also cladded with thermo break insulation system.
Ceiling
Ceiling cladding panel fabricated out of 0.6 mm thick S.S. 304/G.I. powder coated sheet mounted on specially designed aluminium sections & back cladding of 0.6mm G.I. sheet. Panels are insulated with PUF 50 mm thickness.
Flooring
Anti Static & Conductive 2mm PVC
( Poly Vinyl ).
All Poly Vinyl (PVC) Tarkett- Made in Sweden.
Perfect coving for easier cleaning.
Air Handling Unit
Capacity up to 6000 CFM
This system gives 25-30 air changes & 10-20 % fresh air with adjustable damper.
It comprises of return air plenum section, cooling / moisture draining section & fan section. It has all necessary controls & accessories for air & refrigerant side.
It’s elegant design ensures low vibration, noise level & power consumption. Since it is compact & ceiling mounted, it saves floor space.
MATERIAL
Rigid S.S. 304 45 mm thick double skin PUF Panels thickness fitted on thermal break rigid aluminium profile.
UV TUBE
30 Watt G30 T8 lamp which inhibits microbial growth, due to moisture content present in the cooling coil.
FILTER DESIGN
Micro V Filter of 5μ in S.S. 304 frame, S.S. 304 Drain Tray for efficient condensate removal.
AIR VELOCITY
Carrier’s suitable Row DX coil. Air velocity across coil & filter won’t exceed 500 FPM.
MOTOR BLOWER
Variable speed motor blower assembly. (German make Kruger, Max 1.5 H.P.)
Hermetically Sealed Door
The Door Panel is 60mm thick confirming to 438-3:2005 on both sides of 52mm thick pressure injected with noise insulation of 28db as per ISO 717-1:1996. The door blade comes with a vision panel tempered glass IG unit size 300 x 300 mm flushed with the surface of the door blade. Besides EPDM sealing gasket, a special lower sealing gasket with the lip facing the floor is fitted on the bottom profile of the door leaf to ensure 100% hermetic sealing.
S.S. Sealed Door
Double S.S. 304 flushed complete with air tight door frame 1.2 mm thick and shutters 0.8 mm thick S.S. 304 in double skin construction duly insulated with infill material..
Riser Unit
The Door Panel is 60mm thick confirming to 438-3:2005 on both sides of 52mm thick pressure injected with noise insulation of 28db as per ISO 717-1:1996. The door blade comes with a vision panel tempered glass IG unit size 300 x 300 mm flushed with the surface of the door blade. Besides EPDM sealing gasket, a special lower sealing gasket with the lip facing the floor is fitted on the bottom profile of the door leaf to ensure 100% hermetic sealing.
S.S. Sealed Door
Double S.S. 304 flushed complete with air tight door frame 1.2 mm thick and shutters 0.8 mm thick S.S. 304 in double skin construction duly insulated with infill material..
Surgeon Control - Touch Control
Digital Control Panel has 2 pressure indicator gauges, one for room's positive pressure & other for laminar flow system.
It is made in 1.2 mm thick S.S. 304 Sheets. Control switches are Touch Control embedded within the user interface of the Digital Display. Shows elegant Digital Display of temperature, humidity, elapsed time and dimmable light control for ceiling lights.
Pass Box
Complete in S.S. 304 grade 1.2 mm thickness double skin. Size :2'x2'x2' internal.
Automatic Shade Control
Motorised Venetian blinds to control external natural light.
Wall
Powder coated panel, S.S. 304 panel, half powder coated half S.S. & P.V.C vinyl.
Humidity Controller